Data Acquisition, Control, and Laboratory Automation


Data Acquisition and Control Suited to the Application

 
  • High speed data capture:  for some, "fast" may mean gigahertz.  For a botanist, it may mean 1 Hz or less.  (For a geologist, that's yet another regime.)  The IDL has worked with the entire range.
  • Precision data:  up to ppm precision or very high speed means attention to cabling, board layout, precision amplification and filtering.
  • Acquisition of multiple sources, simultaneously requires attention to amplification, speed, and scaling.

Sometimes commercial DAQ equipment is employed; at other times, a circuit must be designed.  For example:

  • For an acquisition system for a Force Plate Actometer, a commercial ADC board can be employed with an IDL-designed circuit.
  • A board for cosmic ray detection requires a custom circuit.  A radar signal is split into four frequency bands, and each is digitized at 2 MHz, then transmitted to embedded FPGA logic.

Lab Automation: Bring the Experimental Process Under Automated Control

 

For example: